Showing posts with label LIB file. Show all posts
Showing posts with label LIB file. Show all posts

19 August

Inputs for Physical Design | Physical Design input files

In this article, we will discuss what are the inputs required to begin the physical design. In the previous article, we have discussed the physical design flow and sanity checks before the floorplan. Inputs required for physical design can be categories broadly into two types. Some inputs are mandatory in all the cases but some are required for a specific purpose. Figure-1 shows the list of inputs required for physical design and categories the mandatory and optional inputs.


Figure-1: Inputs for Physical Design



In the set input files, the first set is design-related files which contain Gate level netlist file and design constraint files. These files come from the synthesis team. Let's briefly see the content of these files.

Gate level netlist: 

This is the synthesized netlist. The synthesis team performs synthesis on RTL code with the standard cell libraries and constraints and converts the RTL code into the gate-level netlist based on available standard cells. This file contains all the instances of design and their connection. 

 

Constraint file: 

Constraint file is popularly known as SDC file by its extension of the file. It contains basically,
  • Units (Time, Capacitance, Resistance, Voltage, Current, Power)
  • System interface (Driving cell, load)
  • Design rule constraints (max fanout, max transition)
  • Timing constraints (Clock definitions, clock latency, clock uncertainty, input/output delay)
  • Timing exceptions (Multi-cycle and false paths)

A detail description of SDC file is explained here

Now some inputs are required which are related to standard cell libraries. These files are provided by the standard cell library vendor and these files are as follow. 


Logical libraries: 

The logical library is also called a timing library or functional library or power library as it contains the functionality, time and power information of cells. This file contains basically the following information of the standard cells or macros. 

  • Timing details of the standard cells / macros ( delay, transitions)
  • Setup and hold time of  standard cells / macros
  • Functionality details of  standard cells /macros
  • Area of standard cells / macros
  • Pin directions and capacitance
  • Leakage power of standard cells / macros 

The logical libraries could be either in liberty format .lib file for Cadence tool or in the form of .db file for Synopsys tool. There are different logical files for different PVT corners. Liberty file is created by doing the standard cell library characterization, so this file is provided by the standard cell library vendor.


Physical libraries: 

The physical library contains the abstract view of the layout for standard cells and macros. LEF file basically contains:

  • Size of the cell (Height and width)
  • Symmetry of cell
  • Pins name, direction, use, shape, layer 
  • Pins location

Physical libraries are in Library Exchange Format (.lef) for the Cadence tools or .CELL and .FRAM form for Synopsys tool. This file is provided by the standard cell library vendor.  


Technology file: 

The technology library is the most critical input to the physical design tool. The technology library contains detail information about all the metal layers, vias and their design rules. This file is in ASCII format and basically contains the following information:

  • Manufacturing grid
  • Layers name (poly | contact | metal1 |via2 )
  • Types and the direction of the metal
  • Pitch
  • Width
  • Spacing 
  • Resistance (per square unit)

The technology file used by the Cadence tool is .techlef format and .tf format by Synopsys tool. 


RC coefficient file: 

TLU file is a short form of "Table Look-Up" is used for RC estimation and extraction or we use QRC file or cap table for the same.

 

MMMC view file: 

Multi-Mode Multi-Corner file is used to generate different analysis views based on different delay corners and constraints modes. Delay corners are defined on library sets and RC corners. There are various library set files based on voltage and temperature values (like ss, ff, typical). 

The above set of files are needed to initiate all the physical design. Some files format is different for the Cadence tool and Synopsys tool. There are some optional files that might be required especially for block-level PnR implementation. These files are as bellow.


Block partition: 

For block-level PnR, we need a defined core area for the block or block partitions which defines the size and shape of the block. Block shape could be a simple rectangular or a complex rectilinear shape.


Pin def: 

For block-level PnR, pin locations have been decided by the Full chip owner and for block-level, we have to use the predecided pin location in order to match the pin locations with other blocks. Generally, it is given in form of a def file. In case of any pin placement issue at the block level, the block owner can inform the person who is placing the pin and if required block owner can also edit the pin placement.


Power plan script: 

For block-level PnR, power plan should be as per the full chip. The power plan has been decided on full chip and in block level, the Power plan should be used as per full chip. Power plan could be given a set of rules or a power plan script (.tcl file).


Power intent (UPF | CPF file): 

Power intent file describes which power rails should be routed to individual block when the block should be powered on or shut down. Unified Power Format (.upf) and Common Power Format (.cpf) are two different formats of power intent files. CPF format is used by the Cadence tool and UPF format by the other tools. We must need this file if the block is having a multi-voltage domain.


Switching activity files (VCD | SAIF): 

SAIF or VCD file is used basically for the dynamic IR analysis in the Physical design. Dynamic IR analysis provides the Dynamic power drop inside the chip based on the switching activities. 


Note:  All the files have described here are very brief, for more details about these files please refer to the "Files in VLSI" section of the blog or our YouTube channel.

Thank you.

08 May

LIB File in Physical Design | Liberty File | .lib file

Lib file is a short form of Liberty Timing file. Liberty syntax is followed to write a .lib file. LIB file is an ASCII representation of timing and power parameter associated with cells inside the standard cell library of a particular technology node. Lib file is basically a timing model file which contains cell delay, cell transition time, setup and hold time requirement of the cell. So Lib file basically contains timing and electrical characteristics of a cell or macros. Lib file is generated and provided to ASIC designer by a standard cell library vendor or Foundry if the foundry provides a standard cell library. 

The information inside the Lib file can be divided into two main parts, in the first part, it contains some information which is common for all the standard cells. To understand it better have a look in the following snapshot of the Lib file.



The common part of Lib file contains 

  • Library name and technology name
  • Units (of time, power, voltage, current, resistance and capacitance)
  • Value of operating condition ( process, voltage and temperature) - Max, Min and Typical 
Based on operating conditions there are three different lib files for Max, Min and Typical corners. In the second part of Lib file, it contains cell-specific information for each cell. The part of Lib file which contains cell-specific information is shown below.


Cell-specific information in Lib file is mainly
  • Cell name
  • PG Pin name
  • Area of cell
  • Leakage power in respect of input pins logic state
  • Pins details
    • Pin name 
    • Pin direction
    • Internal power 
    • Capacitance 
    • Raise capacitance
    • Fall Capacitance
    • Fanout load
A snapshot of Lib file for the pin part is given below.

Timing and power parameter of a cell is obtained by simulating the cell in a variety of operating conditions and data are represented in the Lib file. There are two main techniques to characterize a cell and generated the Lib file.
      • CCS (Composite Current Source)
      • NLDM (Non-Linear Delay Model)
In CCS technique current source is used whereas in NLDM technique voltage source is used to model and derive the Lib parameters. Based on CCS and NLDM technique used for characterizing the cell, we call the corresponding Lib file is CCS Lib file and NLDM Lib file. Since CCS technique is having more controlling parameters as compare to NLDM technique, So CCS Lib file is more accurate. NLDM Lib file has lesser run time mean fast run compare to CCS Lib and also the size of the NLDM file is lesser than that of CCS Lib file.  